The 2GIG-DW10E-900 wireless, E+ extended range encrypted, indoor alarm contact is designed to be installed on doors, windows, jewelry boxes, and many other objects that open and close. The 2GIG DW10E-900 door/window contact sends alarm signals to the 2GIG EDGE control panel (FW 1.3 or later is required), when a magnet mounted near the sensor is moved away from or closer to the sensor's transmitter.
The E+ series provides expanded, reliable security coverage to large, multi-level homes and light commercial facilities The door/window sensor also comes equipped with a cover tamper for additional security. It communicates with the EDGE wireless control panel using the secure 900 MHz frequency spectrum.
Product Features:
Extended wireless range with up to 2KM* (1.2 miles) using 900 MHz spectrum
Thoughtful design and seamless fit with pre-included spacer, enabling more door and window applications
Rounded outer and square interior enable accurate installation, for optimized installer experience
Battery life of up to 8 years reducing frequent replacement and truck rolls
Two-way encrypted communication contributes to enhanced security and reliability
Supports external Normally Open or Normally Closed input
*Wireless range can vary depending on building materials
Mount Sensors within range of the Control Panel: Although the transmitter may have a range of 2KM (1.2 miles) open air, the sensor location can have a significant effect on range. In open/unobstructed situations, the transmitter range may be greater. In adverse wireless conditions, changing the sensor orientation may lead to improved range.
Mount Sensors at Least 4.7 in (12 cm) Above the Floor: Placing sensors slightly above floor level helps to minimize possible sensor damage.
Single vs. Double Door Installation: For single?door installation, mount the sensor on the door frame and the magnet on the door. For double?door installation, mount the sensor on the least?used door and the magnet on the most?used door.
Do Not Expose Sensors to Moisture or Extreme Temperature: It is best to mount sensors in a dry location where the operating temperature do not exceed 32° to 120°F (0° to 49°C).
Keep Sensors and Magnets Away from Metal/Metallic Surfaces: To keep sensors and magnets away from metal or metallic surfaces (for example, foil wallpaper), it is recommended that you use spacers (not included). You should also avoid mounting sensors in areas where there is a large quantity of metal or electrical wiring (for example, near a furnace or in a utility room).
Align Magnet with Sensor: Make sure the alignment arrow on the magnet points to the center alignment mark on the sensor.